Wuhan Municipal Health and Family Planning Commission Medical Research Project(WG17B04);Wuhan Municipal Health and Family Planning Commission Medical Research Project(WG18Q05);Seventh Batch of Young and Middle-aged Medical Backbone Talent Training Projects of Wuhan Municipal Health and Health Commission
目的 采用环介导等温扩增(LAMP)方法检测疟原虫DNA,并评价其检测效果。方法 采集2013-2018年从疟疾流行区回国人员中确诊为疟疾患者的滤纸血样。根据疟原虫的18S rRNA序列,使用PrimerExplorer V5软件设计恶性疟原虫与非恶性疟原虫LAMP引物,建立疟原虫LAMP检测方法,进行敏感性、特异性、灵敏度和扩增效率评价,并与巢式PCR比较。检测钙黄绿素指示剂对LAMP反应的影响。结果 LAMP和巢式PCR各检测96份疟疾患者血样(47份恶性疟血样和49份其他疟疾血样),均检出93份疟原虫阳性。LAMP检测结果显示,恶性疟血样均被检出,非恶性疟假阴性率为2.1%,10份利什曼原虫玻片血、8份日本血吸虫感染兔血和38份健康人血均为阴性,与巢式PCR检测结果具有极高的一致性(Kappa值 = 0.956)。LAMP检测恶性疟原虫、间日疟原虫、卵形疟原虫、三日疟原虫的灵敏度分别为25、3、4、2个疟原虫/μl血。扩增效率检测结果显示,4种疟原虫LAMP反应出现浊度时间(Tt值)均小于60 min,速率曲线峰值(Df)达0.14以上,其中恶性疟原虫扩增效率较高,Tt值为20.4 min,Df达0.16。可视化LAMP检测结果显示,钙黄绿素指示剂对不同种疟原虫LAMP反应延时约8~22 min,Df下降约21%~35%。结论 LAMP技术检测疟原虫有高度敏感性、特异性和灵敏度,且可视,具有在现场及基层医疗机构应用前景。
周水茂 , 涂祖武 , 杨燕 , 陈芳 , 贾西帅 . 环介导等温扩增检测恶性疟原虫与其他疟原虫的效果评价[J]. 中国寄生虫学与寄生虫病杂志, 2020 , 38(4) : 423 -428 . DOI: 10.12140/j.issn.1000-7423.2020.04.004
Objective To detect the DNA of malaria parasites using the loop-mediated isothermal amplification (LAMP) method and evaluate the efficacy of this method.Methods Blood samples on filter papers were collected from confirmed malaria patients returning from endemic areas of other countries during 2013-2018. According to the 18S rRNA sequences of malaria parasites, LAMP primers for Plasmodium falciparum and other species of Plasmodium were designed using the Primer Explorer V5 software. The LAMP method for detecting malaria parasites was established and its sensitivity, specificity, detection limit and amplification efficiency were assessed and compared with the nested-PCR. The effect of calcein indicator on LAMP reaction was tested.Results The LAMP and nested-PCR were performed separately on 96 blood samples, including 47 with P. falciparum and 49 with other species of Plasmodium. Either method found 93 samples as malaria-positive. The LAMP method produced positive results for all the 47 blood samples with P. falciparum, while having a false negative rate of 2.1% among the samples with other Plasmodium spp.. The LAMP method provided negative results for 10 samples with Leishmania, 8 with Schistosomiasis japonicum, and 38 blood samples from healthy participants, highly consistent with the results of nested-PCR (Kappa value, 0.956). The sensitivity of LAMP for P. falciparum, P. vivax, P. ovale and P. malariae was 25, 3, 4, and 2 parasites/μl blood, respectively. Amplification efficiency test showed that the turbity time (Tt) and peak value of rate (Df) of LAMP for the four malaria species were less than 60 min and above 0.14, respectively, of them the amplification efficacy was particularly high for P. falciparum (Tt, 20.4 min; Df, 0.16). In visualized LAMP assay for the four malaria species, using calcein indicator delayed LAMP reaction Tt about 8-22 min, and lower the Df by about 21%-35%.Conclusion The LAMP method is highly sensitive, specific, of low detection limit and has potentials for application on-site in the field and in primary medical settings.
Key words: Plasmodium; LAMP; Nested-PCR; P. falciparum
| [1] | Gao JS. Study on evaluation of specificity and stability of colloidal gold rapid test kit for detection of Plasmodium falciparum/Plasmodium vivax[J]. Strait science, 2019,147(3):3-6. (in Chinese) |
| [1] | ( 高俊松. 恶性疟原虫/间日疟原虫胶体金法快速检测试剂盒稳定性及特异性评估方法研究[J]. 海峡科学, 2019,147(3):3-6.) |
| [2] | Wang ZH, Wei CY, Wang H. Research development on non-coding RNA of Plasmodium falciparum[J]. Chin J Parasitol Parasit Dis, 2018,36(4):409-412. (in Chinese) |
| [2] | ( 王志华, 魏春燕, 王恒. 恶性疟原虫非编码RNA的研究进展[J]. 中国寄生虫学与寄生虫病杂志, 2018,36(4):409-412.) |
| [3] | Hashimoto M, Sakamoto H, Ido YI, et al. In situ loop-mediated isothermal amplification (LAMP) for identification of Plasmodium species in wide-range thin blood smears[J]. Malar J, 2018,17:235. |
| [4] | World Health Organization. World malaria report 2017[R]. Geneva: WHO, 2017. |
| [5] | Zhang L, Feng J, Zhang SS, et al. The progress of national malaria elimination and epidemiolgcal characteristice of malaria in China in 2017[J]. Chin J Parasitol Parasit Dis, 2018,36(3):201-209. (in Chinese) |
| [5] | ( 张丽, 丰俊, 张少森, 等. 2017年全国消除疟疾进展及疫情特征分析[J]. 中国寄生虫学与寄生虫病杂志, 2018,36(3):201-209.) |
| [6] | Hayashida K, Kajino K, Simukoko H, et al. Direct detection of falciparum and non-falciparum malaria DNA from a drop of blood with high sensitivity by the dried-LAMP system[J]. Parasit Vectors, 2017,10(1):26. |
| [7] | Vásquez AM, Zuluaga L, Tobón A, et al. Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening malaria in peripheral and placental blood samples from pregnant women in Colombia[J]. Malar J, 2018,17:262. |
| [8] | Serra-Casas E, Manrique P, Ding XC, et al. Loop-mediated isothermal DNA amplification for asymptomatic malaria detection in challenging field settings: technical performance and pilot implementation in the Peruvian Amazon[J]. PLoS One, 2017,12(10):e0185742. |
| [9] | Imai K, Tarumoto N, Runtuwene LR, et al. An innovative diagnostic technology for the codon mutation C580Y in kelch13 of Plasmodium falciparum with MinION nanopore sequencer[J]. Malar J, 2018,17:217. |
| [10] | Kemleu S, Guelig D, Eboumbou Moukoko C, et al. A field-tailored reverse transcription loop-mediated isothermal assay for high sensitivity detection of Plasmodium falciparum infections[J]. PLoS One, 2016,11(11):e0165506. |
| [11] | Tambo M1, Auala JR, Sturrock HJ, et al . Evaluation of loop-mediated isothermal amplification as a surveillance tool for malaria in reactive case detection moving towards elimination[J]. Malar J, 2018,17:255. |
| [12] | Imai K, Tarumoto N, Misawa K, et al. A novel diagnostic method for malaria using loop-mediated isothermal amplification (LAMP) and MinIONTM nanopore sequencer[J]. BMC Infect Dis, 2017,17:621. |
| [13] | Port JR, Nguetse C, Adukpo S, et al. A reliable and rapid method for molecular detection of malarial parasites using microwave irradiation and loop mediated isothermal amplification[J]. Malar J, 2014,13:454. |
| [14] | Stephanie PJ, Norman JP, Maniphet VX, et al. PCR as a confirmatory technique for laboratory diagnosis of malaria[J]. J Clin Microbiol, 2006,44(3):1087-1089. |
| [15] | Fuehrer HP, Stadler MT, Buczolich K, et al. Two techniques for simultaneous identification of Plasmodium ovale curtisi and Plasmodium ovale wallikeri by use of the small-subunit rRNA gene[J]. J Clin Microbiol, 2012,50(12):4100-4102. |
| [16] | Polley SD, Mori Y, Watson J, et al. Mitochondrial DNA targets increase sensitivity of malaria detection using loop-mediated isothermal amplification[J]. J Clin Microbiol, 2010,48(8):2866-2871. |
| [17] | Zhou SM, Wang CX, Wu K, et al. Application of nested PCR in diagnosis of imported malaria[J]. Chin J Parasitol Parasit Dis, 2011,29(1):43-45. (in Chinese) |
| [17] | ( 周水茂, 王重新, 吴凯, 等. 巢式PCR技术在输入性疟疾监测中的应用[J]. 中国寄生虫学与寄生虫病杂志, 2011,29(1):43-45.) |
| [18] | Jia XS, Zhou SM, Yang Y, et al. Detection of two kinds of imported Plasmodium ovale by nested PCR in Wuhan[J]. Chin Trop Med, 2018,18(5):423-426. (in Chinese) |
| [18] | ( 贾西帅, 周水茂, 杨燕, 等. 武汉市两种输入性卵形疟巢式PCR检测[J]. 中国热带医学, 2018,18(5):423-426.) |
| [19] | Port J R, Nguetse C, Adukpo S, et al. A reliable and rapid method for molecular detection of malarial parasites using microwave irradiation and loop mediated isothermal amplification[J]. Malar J, 2014,13:454. |
| [20] | Li M, Yang H, Zhou HJ, et al. World Health Organization-external competency assessment of malaria microscopists in china[J]. Chin J Parasitol Parasit Dis, 2018,36(5):499-509. (in Chinese) |
| [20] | ( 李美, 燕贺, 周何军, 等. WHO对中国疟原虫镜检能力外部评估与结果分析[J]. 中国寄生虫学与寄生虫病杂志, 2018,36(5):499-509.) |
| [21] | De Koninck AS, Cnops L, Hofmans M, et al. Diagnostic performance of the loop-mediated isothermal amplification (LAMP) based illumigene ? malaria assay in a non-endemic region[J]. Malar J, 2017,16:418. |
| [22] | McCreesh P, Mumbengegwi D, Roberts K, et al. Subpatent malaria in a low transmission African setting: a cross-sectional study using rapid diagnostic testing (RDT) and loop-mediated isothermal amplification(LAMP) from Zambezi region, Namibia[J]. Malar J, 2018,17:480. |
| [23] | Hans K, Ralf M H, Miriam H, et al. Poor diagnostic performance of a species-specific loop-mediated isothermal amplification (LAMP) platform for malaria[J]. Eur J Microbiol Immunol (Bp), 2018 , 8(4):112-118. |
| [24] | Kudyba HM, Louzada J, Ljolje D, et al. Field evaluation of malaria malachite green loop-mediated isothermal amplification in health posts in Roraima state, Brazil[J]. Malar J, 2019,18:98. |
| [25] | Tegegne B, Getie S, Lemma W, et al. Performance of loop-mediated isothermal amplification (LAMP) for the diagnosis of malaria among malaria suspected pregnant women in Northwest Ethiopia[J]. Malar J, 2017,16:34. |
| [26] | Sattabongkot J, Suansomjit C, Nguitragool W, et al. Prevalence of asymptomatic Plasmodium infections with sub-microscopic parasite densities in the northwestern border of Thailand: a potential threat to malaria elimination[J]. Malar J, 2018,17:329. |
/
| 〈 |
|
〉 |